LED Neon Flex Logo

Vivid Wave: Silicone CORE - 24V

technical data sheet

Legacy Product CODE

SF16E0012WD22K24DE

NEW PRODUCT CODE

V1F2W1H8E3VP

PHysical

electrical

11.81in (300mm)
11.81in (300mm)
11.81in (300mm)

operating voltage

24V DC

Circuit type

Constant Voltage (CV)

power consumption

2.74W/ft (9W/m)

IC Type

N/A

2200K

fixture specifications

led function

Static

led chip + CRI

DOM LED Chip + CRI80

led count

29 LEDs/ft (96 LEDs/m)

temperatureS

Temperature Icon
Ambient Operating
-40°F to 140°F (-40°C to 60°C)
thermal management
Free air convection
Temperature Icon
Ambient installation
-40°F to 140°F (-40°C to 60°C)
Temperature Icon
max mounting surface
185°F (85°C)
Temperature Icon
fixture storage
-40°F to 140°F (-40°C to 60°C)
Temperature Icon
humidity non condensing
0-95%

Pixel/unit + chip

order unit (Cutting Unit)

max run length

0.82in (20.8mm) (2 LEDs)

1 Connector
full / dynamic loads

39.4ft (12m) / N/A

2 Connectors
full / dynamic loads

78.7ft (24m) / N/A

safety / testing

jacket/base + LENS color

White + Diffused

testing

Tested to UL2108 Class 2 by Underwriters Laboratory for use in the USA and Canada. Exceeds ANSI C78.377A, CE, and RoHS standards. Must be used under Class 2 ratings to maintain certification.

cord color

White (Black available upon request)

connectors

Swivel, Click, Snap, DIY Submersible, Silicone Seamless & Silicone Submersible

mounting

Aluminum: Basic, Recessed, Silicone Grip, Recessed Silicone Grip, Flexible, Raceway and Raceway Suspended. Silicone Flexible, Stainless Steel Clip and Plastic Reinforced

optical pARAMETERS

color BReakdown

2200K

Fixture cri

80

fixture color tolerance

3 SDCM

wavelength/cct

2238±82K

led cri

82~87

led color tolerance

<2.3SDCM

lumen count

152lm/ft (500lm/m)

BEEM angle

lumen maintenance

NOTES

*Maximum IP and IK ratings achievable with appropriate accessories.Max run length is based on silicone seamless connectors and excludes connector length, see connector specs for details.Silicone products maintain ≤3 SDCM within a production run and <5 SDCM between production runs.Max run length is based on static full load unless otherwise noted for dynamic use.For runs over 65.62ft (20m), recommended to limit each to 65.62ft for easier handling.Running length is based on voltage drop testing with a 0.3m (0.98ft) cable.

united states

1075 american pacific dr.,
sutie A, henderson, NV 89074

canada

470 Edinburgh Drive
2nd Floor, Moncton nb, E1E 2L1

disclaimer

glls, reserves the right to make any design changes for continuous improvement which will not affect the overall appearance or performance

version
1.0
revision
June 8, 2025
Export PDF/Print Icon