GLLS Logo + Slogan: Black
LED Neon Flex Logo

Vivid Wave XL: Silicone - 24V

technical data sheet

Legacy Product CODE

SF19E0013WERGB24DC

NEW PRODUCT CODE

V1G2W5S1J2CF

PHysical

electrical

11.81in (300mm)
11.81in (300mm)

operating voltage

24V DC

Circuit type

Constant Current (CC)

power consumption

5.03W/ft (16.5W/m)

IC Type

N/A

RGB
10 Year Warranty
24V DC
IK10 Protection*
IP68 Protection*
INDOOR/
OUTDOOR
FLAME
RESISTANT
UV
RESISTANT
SOLVENT
RESISTANT
SALT WATER
RESISTANT
DIMMABLE
FIXTURE.
RDM/
DMX.

fixture specifications

led function

SPI/Pixel

led chip + CRI

Epistar SMD LED Chip

led count

25 LEDs/ft (84 LEDs/m)

temperatureS

Temperature Icon
Ambient Operating
40 to 113? (40 to 45?)
thermal management
Free air convection
Temperature Icon
Ambient installation
40 to 122? (40 to 50?)
Temperature Icon
max mounting surface
185? (85? )
Temperature Icon
fixture storage
40 to 140? (40 to 60?)
Temperature Icon
humidity non condensing
0-95%

Pixel/unit + chip

order unit (Cutting Unit)

max run length

3.28in (83.3mm) (7LEDs)

1 Connector
full / dynamic loads

32.8ft (10m) / Not Recommended

2 Connectors
full / dynamic loads

65.6ft (20m) / Not Recommended

safety / testing

jacket/base + LENS color

White + Diffused

testing

UL2108 Class 2, CEEMC, IS 10322

cord color

White (Black available upon request)

connectors

End, side & bottom lead wires

mounting

Serrated Aluminum Profile, Flange Serrated Aluminum Profile, Bendable Serrated Aluminum Profile

optical pARAMETERS

color BReakdown

R; G; B; R+G+B

Fixture cri

N/A

fixture color tolerance

N/A

wavelength/cct

618624nm; 522530nm; 468474nm; N/A

led cri

N/A

led color tolerance

3nm; 3nm; 3nm; N/A

lumen count

40lm/ft (130lm/m); 104lm/ft (340lm/m); 20lm/ft (65lm/m); 163lm/ft (535lm/m)

lumen maintenance

70,000 Hours L70 @ 25°C : 90,000 L50 @ 25°C 50,000 Hours L70 @ 50°C : 70,000 Hours L50 @ 50°C

NOTES

1) Max Run Length: Dynamic = when the R, G, B channels are not operating at 100%, Full Load = when the R, G, B channels are operating at 100%. 2) It is not recommended to use dynamic load calculations to determine max distance for this profile.

*The highest achievable IP rating with appropriate connector accessories & The highest achievable IK rating with appropriate mounting accessories.

*The constant Current (CC) Integrated Circuit is only used to extend max run length. Do not use a constant Current (CC) power supply in line with the fixture as it may cause damage.

united states

1075 american pacific dr.,
sutie A, henderson, NV 89074

canada

378 coverdale rd.,
unit a, riverview nb, E1B 3J7

disclaimer

glls, reserves the right to make any design changes for continuous impovement which will not affect the overall apperance or performance

version
1.0
revision
July 18, 2024